M591 P1 C"e0stop" S1 D0 filament monitor connected to E0 endstop G31 X0 Y0 Z0.9 set Z probe trigger value, offset and trigger height M558 P9 C"^zprobe.in" A5 H4 F100 T6000 set Z probe type to bltouch and the dive height + speeds M950 S0 C"exp.heater3" create servo pin 0 for BLTouch M574 Z1 S2 configure Z-probe endstop for low end on Z M574 Y2 S1 P"!ystop" configure active-high endstop for low end on Y via pin ystop M574 X1 S1 P"!xstop" configure active-high endstop for low end on X via pin xstop M906 X1400 Y1400 Z2200 E700 I1 Set motor currents (mA) and motor idle factor in per cent M566 X480 Y480 Z5 E270 Set maximum instantaneous speed changes (mm/min) M350 E32 I0 Configure microstepping without interpolation M350 Z8 X16 Y16 I1 Configure microstepping with interpolation M575 P1 B57600 S1 Set auxiliary serial port baud rate and require checksum (for PanelDue) M540 PBE:EF:DE:AD:FE:ED MAC Address (only needed if you have more than one Duet 0.6 or 0.8.5 on the same network) Machine password (used when you connect Duet Web Control or via FTP) M550 Deluxe600 Machine name (can be anything you like)